NEC 210-52 Outdoor Receptacles, accessible at grade level and no more than 6 1/2 feet above grade, shall be installed at the front and back of a dwelling. NEC 210-52 Receptacles shall not be installed in a face up position on work surfaces or countertops. NEC 210-52 A receptacle shall be installed at each counter space 12 inches or wider, and at each island counter or peninsular space larger than 12 inches by 24 inches. Countertop spaces separated by, range tops, sinks or refrigerators are separate spaces. NEC 210.52 General Circuitry kitchen A receptacle outlet shall be installed at each counter space 300 mm or wider, and at each island counter or peninsular space 600 mm by 300 mm or larger. NEC 210.52 General Circuitry kitchen At kitchen countertops, receptacle outlets shall be installed so that no point along the wall line is more than 600 mm measured horizontally from a receptacle outlet in that space. NEC 210-52 At kitchen Countertops, receptacle outlets shall be installed so that no point along the wall line (measured horizontally) is more than 24 inches from a receptacle outlet in that space.
![nec residential receptacle requirements pdf images nec residential receptacle requirements pdf images](https://images.homedepot-static.com/productImages/711edb70-1104-4627-9a9d-32744459b49d/svn/black-leviton-electrical-outlets-receptacles-t5825-e-64_400.jpg)
An outlet shall be installed in each wall space 2 feet or more in width. NEC 210-52 Generally, receptacle outlets in habitable rooms shall be installed so that no point along the floor line (measured horizontally) in any wall space is more than 6 feet from an outlet in that space. NEC 210-52 Outdoor receptacles, accessible at grade level and no more than 6 1/2 feet above grade, shall be installed at the front and back of a dwelling. NEC 210-52 At kitchen countertops, receptacle outlets shall be installed so that no point along the wall line (measured horizontally) is more than 24 inches from a receptacle outlet in that space. NEC 210-52 Receptacles installed in the kitchen to serve countertop surfaces shall be supplied by not less than two separate small appliance branch circuits. Grounding type receptacles supplied by a GFCI shall be marked "GFCI Protected" and "No Equipment Grounded." If more information is needed to complete your project, there are many books available at your local Home Improvement Center that are designed to help homeowners. NEC 210-7 where a grounding means does not exist in the receptacle enclosure, the installation shall comply with (a), (b), or (c), a) a non- grounding type receptacle may be installed b) a ground-fault circuit-interrupter receptacle may be installed and shall be marked "No Equipment Ground." Ĭ) a grounding type receptacle may replace a non-grounding type receptacle when supplied through a ground-fault circuit interrupter receptacle. Contact your local building authority for complete information. NEC 210-7 Receptacle Outlets shall be of the grounding type, be effectively grounded, and have proper polarity.Ĭode Adoption Information: The codes shown are examples only and may not be current or accurate for your application or jurisdiction.
#Nec residential receptacle requirements pdf images code#
Most local residential electrical codes are based on the NEC-the National Electrical Code-a model code that provides guidelines on which local communities can model their own residential codes.Introduction to Electrical Codes for Outlets and Receptacles The best of both worlds! This article was also written by the knowledgeable folks over at ! We hope it helps you understand the code requirements so you can sit back and relax knowing that your kitchen is safe, and will pass inspection.Īn electrical code is an official set of guidelines that specifies how various aspects of an electrical system should be installed.
#Nec residential receptacle requirements pdf images series#
This article on code requirements was recently updated, and we think it gives some great info (some not necessarily kitchen focused, but great info nonetheless) for those who are planning to renovate their kitchen! The code has been slightly changing over the past few years, but we're proud to say that our S-Box™ outlet series (both 15 amp and 20 amp) STILL are splash rated, GFCI, and meet all code requirements for your kitchen outlet needs, while staying hidden from sight in your countertop.